Measure power use for a solar Meshtastic node

Measure the node's energy use before choosing a solar panel and battery. One current reading is not enough. Meshtastic nodes spend much of their time listening and draw more power when they transmit. Measure energy over time​ Power is measured in watts. Multiply voltage by current to calculate it: 5 V × 50 mA = 250 mW. Energy is power used over time, measured in watt-hours (Wh). A node drawing 250 mW for 24 hours uses 6 Wh. Your panel and battery need to supply that daily energy, plus extra for cloudy days and system losses. Use a meter or bench power supply that totals watt-hours or amp-hours over time. Most handheld multimeters show a momentary reading, not accumulated energy. Check that

…