The dial magnifiers quote 4096 encoder steps, but the datasheet's error spec is plus or minus 1 degree, which is a quarter of a dial number. Does that cancel when you graph contact points?
The digital dial magnifier builds that have gone around here all quote a resolution number, so I went and read the datasheet for the part to find out what the accuracy number was. They are not the same number and the gap is wider than I expected. I would like people who actually manipulate to tell me whether it matters. The two builds I could find source for: The ESP32-S3 one posted here in January 2025 uses an AS5600 magnetic encoder, 4096 steps per revolution. On a 100 number dial that is 40.96 steps per number. The builder called that way more than we need, and on resolution they are plainly right. The other one on GitHub uses a quadrature encoder listed at 1000 pulses per revolution
…