Grounded Well-Condition Anomaly Detection on the Volve Field: Constructed Labels, a Baseline, and a Dual-Head Model
arXiv:2608.05685v1 Announce Type: new Abstract: Most public benchmarks for machine-condition monitoring come from test rigs, where faults are induced on purpose and every event is known. Real production fields rarely offer that. They give you sensor histories with no fault log attached, which is exactly the situation where an anomaly-detection method has to invent its own labels, and where quiet assumptions can slip in unnoticed. We work with the open Volve field data released by Equinor and take two things seriously that such datasets usually skip. First, we build anomaly labels that are not just patterns in the numbers but are checked against what the field's own engineering documents say
…